Your browser doesn't support javascript.
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Añadir filtros

Base de datos
Tipo del documento
Intervalo de año
1.
PLoS One ; 16(7): e0241734, 2021.
Artículo en Inglés | MEDLINE | ID: covidwho-1325370

RESUMEN

Personal protective equipment (PPE) is crucially important to the safety of both patients and medical personnel, particularly in the event of an infectious pandemic. As the incidence of Coronavirus Disease 2019 (COVID-19) increases exponentially in the United States and many parts of the world, healthcare provider demand for these necessities is currently outpacing supply. In the midst of the current pandemic, there has been a concerted effort to identify viable ways to conserve PPE, including decontamination after use. In this study, we outline a procedure by which PPE may be decontaminated using ultraviolet (UV) radiation in biosafety cabinets (BSCs), a common element of many academic, public health, and hospital laboratories. According to the literature, effective decontamination of N95 respirator masks or surgical masks requires UV-C doses of greater than 1 Jcm-2, which was achieved after 4.3 hours per side when placing the N95 at the bottom of the BSCs tested in this study. We then demonstrated complete inactivation of the human coronavirus NL63 on N95 mask material after 15 minutes of UV-C exposure at 61 cm (232 µWcm-2). Our results provide support to healthcare organizations looking for methods to extend their reserves of PPE.


Asunto(s)
COVID-19/prevención & control , Contención de Riesgos Biológicos/métodos , Descontaminación/métodos , Pandemias , SARS-CoV-2/efectos de la radiación , Rayos Ultravioleta , COVID-19/transmisión , COVID-19/virología , Relación Dosis-Respuesta en la Radiación , Equipo Reutilizado , Personal de Salud/educación , Humanos , Laboratorios/organización & administración , Máscaras/virología , Respiradores N95/virología , Radiometría/estadística & datos numéricos , SARS-CoV-2/patogenicidad , SARS-CoV-2/fisiología
2.
Am J Infect Control ; 49(4): 424-429, 2021 04.
Artículo en Inglés | MEDLINE | ID: covidwho-917197

RESUMEN

BACKGROUND: Filtering facepiece respirators (FFR) are critical for protecting essential personnel and limiting the spread of disease. Due to the current COVID-19 pandemic, FFR supplies are dwindling in many health systems, necessitating re-use of potentially contaminated FFR. Multiple decontamination solutions have been developed to meet this pressing need, including systems designed for bulk decontamination of FFR using vaporous hydrogen peroxide or ultraviolet-C (UV-C) radiation. However, the large scale on which these devices operate may not be logistically practical for small or rural health care settings or for ad hoc use at points-of-care. METHODS: Here, we present the Synchronous UV Decontamination System, a novel device for rapidly deployable, point-of-care decontamination using UV-C germicidal irradiation. We designed a compact, easy-to-use device capable of delivering over 2 J cm2 of UV-C radiation in one minute. RESULTS: We experimentally tested Synchronous UV Decontamination System' microbicidal capacity and found that it eliminates near all virus from the surface of tested FFRs, with less efficacy against pathogens embedded in the inner layers of the masks. CONCLUSIONS: This short decontamination time should enable care-providers to incorporate decontamination of FFR into a normal donning and doffing routine following patient encounters.


Asunto(s)
COVID-19/prevención & control , Descontaminación/instrumentación , Sistemas de Atención de Punto , Dispositivos de Protección Respiratoria/virología , SARS-CoV-2 , Rayos Ultravioleta , COVID-19/virología , Descontaminación/métodos , Equipo Reutilizado , Humanos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA